History-File of FB4-Firmware V1.25c 27.3.2015 - Release VZ-9plus-3, VZ-9plus, VZ-C12-2, VZ-C12-3, VZ-3 - Improved ethernet connection handling V1.25b 12.11.2014 - Release VZ-9plus-3, VZ-9plus, VZ-C12-2, VZ-C12-3, VZ-C32, VZ-C32-3, VZ-3, VZ-P18, VZ-P38 - Renewed Java certificates V1.25a 09.04.2014 - Release VZ-9plus-3, VZ-9plus, VZ-C12-2, VZ-C12-3, VZ-C32, VZ-C32-3, VZ-3, VZ-P18, VZ-P38 - Fixed webserver security hole: Generic Web Server Directory Traversal Vulnerability - Fixed bug in web osd xml parser - Swapped icons on the web remote control V1.24b 13.11.2013 - Release VZ-9plus-3, VZ-9plus, VZ-C12-2, VZ-C12-3, VZ-C32, VZ-C32-3, VZ-3, VZ-P18, VZ-P38 - Added mirror center bit to rc features for Prof - Support for encrypted passwords - Signed Java applets with certificate from a CA - Improved SIP authentication - Changed adjustment static IP from 10.0.0.160 to 192.168.60.7 - Fixed negative zoom values - Fixed RC applet not showing if VZ is switched off V1.24a 19.09.2013 - Release VZ-9plus-3, VZ-9plus, VZ-C12-2, VZ-C12-3, VZ-C32, VZ-C32-3, VZ-3, VZ-P18, VZ-P38 - Improved power off mode for use with automatic DVI/HDMI switches - Reintroduced _243 zoom limit command - Refurbished OSD menu - Fixed snapshot blocking picture transfer when internal memory is full - Dont restrict single user ip access SIP to ethernet mode AUTH any more - Added 4 channel SIP authentication - Added device search using multicast - Fixed VZ-3 streaming resolution table - Fixed VZ-3 menu call in extern mode - Added mirror center command to wolfprot for VZ-P18 and VZ-P38 - Added FTP feature - Added possibility of sending picture as email or to FTP server with wolfprot snapshot command (excluding VZ-3) - Added email function to capture page - Cleaned up webserver status page - Added possibility to update firmware of device over the internet - Support for new DDR - Raised number of possible ethernet connections from 64 to 128 V1.22d 22.08.2013 - Release VZ-3 - Support of new revision of mainboard V1.22c 04.09.2012 //Betaversion: Has been shipped to selected customers - Release VZ-9plus-3, VZ-9plus, VZ-C12-2, VZ-C12-3, VZ-C32, VZ-C32-3, VZ-3, VZ-P18, VZ-P38 - Fixed 720p/60 resolution and SXGA+/60 frequency - Fixed zero length passwords V1.22b 15.03.2012 - Release VZ-9plus-3, VZ-9plus, VZ-C12-2, VZ-C12-3, VZ-C32, VZ-C32-3, VZ-3, VZ-P18, VZ-P38 - Fixed startup problem when unit switched off and back on in less then 3 seconds (was introduced with V1.22a) - Fixed Quick Setup Guide not showing up if unit is switched on with soft power on switch V1.22a 02.02.2012 - Release VZ-9plus-3, VZ-9plus, VZ-C12-2, VZ-C12-3, VZ-C32, VZ-C32-3, VZ-3, VZ-P18, VZ-P38 - Added frame number and status text number to new Wolfprot block command Flags and Units2 - Fixed USB 3x3 view after returning from 1x1 view while loading next pictures - Fixed occasional blue stripe in VZ-3 camera - Added new buttons to Wolfprot features command (0x16), Pos/Neg, Pos/Blue, Black/White, VZ, Mem, USB, PiP - Enabled menu in Wolfprot features (0x16) - Fixed demo mode - Changed power LED in demo modes to not blinking. Solves problem with shut down in demo modes - Added single IP authentication - Improved stability of ethernet and USB connections when working with Connectivity2 - Fixed booting in case NAND flash is not dedected - Extended device discovery daemon with additional info - Signed applets to avoid necessity of .java.policy file - Support for BPG LED - Compiled Java applets with 1.6.0_29 JDK - Removed Turkish from OSD - Updated timezones - Made Touchhead compatible to new flash devices - Hide OSD and status messages while in extern mode - Allow focus, iris, af in PIP mode when started from USB or memory - Fixed USB stick mount at startup V1.21d 01.09.2011 - Release VZ-9plus-3, VZ-9plus, VZ-C12-2, VZ-C12-3, VZ-C32, VZ-C32-3, VZ-3 - Improved firmware update, avoiding occasional failure - Fixed occasional inverted colors at startup V1.21c 26.07.2011 - Release VZ-9plus-3, VZ-9plus, VZ-C12-2, VZ-C12-3, VZ-C32, VZ-C32-3, VZ-3 - Implemented resolution reset for VZ-3 - Improved AF - Implemented commands 0x25 and 0x26 in Wolfprot - Fixed some texts in German OSD - Improved Flangeback in adjustment menu V1.21b 12.07.2011 - Release VZ-9plus-3, VZ-9plus, VZ-C12-2, VZ-C12-3, VZ-C32, VZ-C32-3, VZ-3 - Fixed changing of admin password - Added Deep Power Down to WebOSD - Added Language to WebOSD - Blocked Item Reset (Long <7>) when in Help - Fixed return from Help while in edit mode (multiple red letters appeared) - Added "Preview Output" Help page - Removed Icons for Height Status Info - MISC SETTINGS renamed to MISCELLANEOUS SETTINGS - Renamed Multicast Port to Streaming Port and fixed helptext - Removed "Reset lamp hours" for all devices with LED light - Blocked AF in Height adjustment - Fixed Resolution Display info on Web Status Page when Testing resolution was executed - Update Operating Hours on Web Status Page when changed in Adjustment Menu - Fixed Output Resolution Line for VZ-3 (Toggled between DVI and DVI/RGB) - Added UNICAST streming - Added Network Check to Adjustment - Fixed VZ locking when ethernet cable is too long (>100m) - Fixed Multicast parallel with 1 Singlecast - Fixed Restore XML when VZ in ImgTurn Mem mode - Fixed SFK list - Fixed language in Quick setup (request was missing) - Fixed wrong Image Format when VZ is switched off - Fixed QuickSetupCount V1.21a 31.05.2011 - Release VZ-9plus-3, VZ-9plus, VZ-C12-2, VZ-C12-3, VZ-C32, VZ-C32-3, VZ-3 - Initial Release VZ-3 - Discontinued HP Serial Protocol - Reworked OSD menu - Added German and Turkish language support - Implemented new behavior for VIEW button - Support of latest IR remote control - Fixed Black/White SFK when VZ was power cycled in color mode Black/White - Fixed menu not showing up in USB mode when invoked with legacy protocol - Fixed WebOSD changing network settings - Extended multicast restable - Fixed 3x3 mode when VZ was in FREEZE state - Fixed SNAPSHOT memory overwrite - Changed Auto Snapshot and Erase Memory function V1.20h 01.09.2011 - Release VZ-P18, VZ-P38 - Improved firmware update, avoiding occasional failure V1.20g - Release VZ-P18, VZ-P38 - Fixed sporadic reboot V1.20f - Release VZ-P18, VZ-P38 - Added IR support V1.20e - Release VZ-P18, VZ-P38, VZ-C32 - Improvements for internal adjustment V1.20d - Release VZ-P18, VZ-P38, VZ-C32 - Fixed Memory Off command - Changed Auto Snapshot and Erase Memory function - Improved touchhead power up behaviour - Improved mirror power up behaviour - Implemented Wolfprot WVC_DESCRIPTION command - Improved focus fine tuning - Improved focus tracking - Compiled Java applets with 1.6.0_20 JDK - Improved speed of firmware update V1.20c - Release VZ-P18, VZ-P38, VZ-C32 - Fixed JPEG encoder for very high contrast images - Fixed focus problem when rf link is lost (VZ-P18, VZ-P38) - Fixed double commands from remote control (VZ-P18, VZ-P38) - Fixed OPAF stopping when rf link is lost (VZ-P18, VZ-P38) - Improved recovery from lost rf link (VZ-P18, VZ-P38) - Improved charging management of remote control battery (VZ-P18, VZ-P38) - Fixed remote control from unintentionally entering the firmware update mode (VZ-P18, VZ-P38) - Fixed deep standby mode V1.20b - Release VZ-9plus-3, VZ-9plus, VZ-C12-2, VZ-C12-3, VZ-C32, VZ-C32-3, VZ-P18, VZ-P38 - Fixed light mask for VZ-C12-2 and 16:10 resolutions - Support for Cancel button in firmware update - On loss of link, stop commands will be sent with 1 sec delay - Fixed race condition in DHCP when cable is plugged in after start - Support for 1080p/30 resolution - View key also switches off memory zoom V1.20a - Release VZ-9plus-3, VZ-9plus, VZ-C12-2, VZ-C12-3, VZ-C32, VZ-C32-3, VZ-P18, VZ-P38 - Initial Release VZ-P18, VZ-P38 - Fixed 12h format - Implemented visualizer behaviour according to vz_state_matrix - Made extern function available in 3x3 picture mode - Added deep power down mode - Added picture in picture feature - Improved presentation mode - Made extern function available in 3x3 picture mode - Fixed legacy ethernet protocol commands 24, 167, 168 - Improved startup for VZ-9plus3 with 100V mains - Implemented firmware update with USB stick V1.12a - Quality of external input improved V1.11b - Fixed Bug "Light on" command for legacy protocol V1.11a - Initial Release VZ-9plus-3 - Real time clock for Log and USB host - Added support for 12h clock - Improved colors for VZ-C12-3 and VZ-9plus-3 - Presentation mode for USB host, scaling for all aspect ratios - Added Log to web interface - Added quick setup - Keystone correction and USB host is now also available on 3-CCD units V1.10c - Initial release VZ-C32-3 - Full support for 4:3, 16:9 and 16:10 resolutions on external input - Added Keystone Correction to OSD - Fixed mime types - Added IMAGE TURN to SFK functions - Fixed 4:3, 16:9, 16:10 auto detection when output format is AUTO V1.10b - Updated WXGA/60 and WSXGA/60 to CVT standard V1.10a - Enabled USB host - Added keystone correction - Added support for 16:10 resolutions - Added support for JPEG in digital zoom, VIEW and for stored images - Added automatic detection of streaming format - Messages "DVI-Device added", "RGB-Device added", "Preview-Device added" moved to OSD Level VERBOSE - Support for JVM > 1.6.0_10 - Added support for Menu control command 0x99 - Fixed images to be accessible in Ethernet-Mode CTRL Only - Changed AMX string to support new driver version - Fixed RS232 timeouts - Added NTP support for date and time - Fixed Image Turn Freeze for USB and ETH - Fixed multiple red bars after returning from Help in menus where digits or numbers are entered V1.02a - Fixed WebOSD - Added singlecast support - Added authentication - Ethernet-Mode will be reset to FW+CTRL+IMG - Display Logo will be reset to ON V1.01b - Initial Release for 3CCD Ceiling Visualizer - No OSD menu and messages on frozen outputs - Further useful improvements V1.01a - Initial Release for 1CCD Ceiling Visualizer - Status Line on Preview/LCD Monitor - Freeze Mode improved - PowerON Preset improved, Iris can be preset as well - Further useful improvements V1.00a - Initial Release