History-File of FB3-firmware V2.06b - Internal update only (support new hardware produced in 2009) V2.06a - No DDC scanning when output resolution is set manually - Fixed Bug: Wrong behavior of lamp voltage [Professionals and Ceiling only] - Fixed Bug: Pixel calibration with new remote control (extern button) - Fixed Bug: Heightadjustment with new remote control [for Ceiling only] - Some minor features for adjustment/QC V2.05a - Ethernet: DHCP use Lease Time according to RFC2131 (renew and rebind time) - Ethernet: Added hostname to DHCP packet - Fixed Bug: Brightness oscillation - Fixed Bug: Automatic height adjustment cannot abort by pressing menu button [for Ceiling only] - Fixed Bug: Factory reset does not update detail setting. - Fixed Bug in email communication - Some minor features for adjustment V2.04a - New output settings menu: Resolution and picture size is displayed in menu. - Improved Extern In: Added 16:9 formats (1280x720, 1360x768, 1440x900, 1920x1080) - Change resolution WXGA to CVT standard (1360x768) - Improved Ethernet: Larger Remote Control for Internet Explorer 7 - Added Pixel Calibration in OSD Extra Menu - Fixed Bug: Menusetting Extern In on LCD can not be modified [for VZ9plus only] - Fixed Bug: SetFocusPos via RS232 does not work [for VZ27plusē and VZ57plus only] V2.03d - Fixed Bug: Pixel noise at startup. V2.03c - Internal Update - Fixed Bug: Wrong RS232 return value for One-Push-AF [Professionals and Ceiling only] V2.03b - Old picture not visible at startup - New return values for S1_GET_PORTRAIT command (serial protocol): 0: 0°, 1: -90°, 2: 180°, 3: +90° V2.03a - VZ-27plus-II support added - New remote control support added - ImageTurn in 16:9 mode shows 3:4 picture (units with synchronised lightfield change light mask) - Auto Exposure more stable - Changed Resolution SXGA+ (1360 x 1024) to 1400 x 1050 for 60 Hz and 75 Hz - Improved shading in 3-CCD units - Text Enhancer assignable to Preset Settings - OSD Menu and Menu Help adapted V2.02e - Internal update V2.02d (VZ9P only): - VZ9P support added V2.02c: - Internal update V2.02b: - Fixed bug: Focus was lost when zooming with USB, Ethernet or RS232 (for C12/C32 only) V2.02a: - Added zoom limitation to custom serial mode (for C12/32 only, for more information contact Wolfvision support) - Fixed bug in HD-Resolution 1080p (official timing) - Support new zoom wheel, improved OSD menu control with zoom wheel - Fixed bug in ethernet part: some html pages had wrong links - Improved One-Push-Auto-Focus (for C12/C32 only) - Improved noise reduction - New OSD menu: sectional to basic and advanced settings - New demo mode adapted to current units V2.01a: - Attention: Memories get erased after firmware update - Digital noise reduction added - "RGB/Preview-Device added" message fixed - ShowAll picture now also available on USB and Ethernet - Improved white balance at startup - Improved auto height adjustment: light focus is sharper - Video OFF setting added: New units are shipped with video switched OFF V2.00c: - Internal update (Laser supports new hardware) V2.00b: - Fixed bug: Firmware backup was not installed properly V2.00a: - Minor bug fixes (improved HD support) - New version number because of major improvements since version 1.30a (sRGB color precision, Ethernet/LAN features) V1.31a: - Fixed bug: Correction of lightfield synchronization (for ceiling and professional units) V1.30c: - Fixed some minor bugs in Adjustment V1.30b: - Fixed bug: sporadic wrong behavior of Ethernet - Fixed a bug in Manual White Balance: If a One-Push-WB was successful and you like to change the values manually, the change has no effect. - Fixed some minor bugs in Adjustment V1.30a: - Color Precision Update (Adaptation to sRGB color standard) - NEW ETHERNET/LAN FEATURES (see Ethernet/LAN Manual on WolfVision homepage) Addition of status page Email notification (can be configured on the homepage of the unit) Correct unit picture on start-up page (internal WolfVision change because of different models) Picture transfers are in BMP (without compression loss) Faster live preview picture (used to be 2frames/s, now 5frames/s) Control Only Mode (needs to be activated in OSD Menu): Either the Remote Control or Status Information page can be opened. - Lamp hours will be documented for each individual bulb. To see and reset the lamp hours there is a new item line in the sub menu (push the menu button for 4 seconds for the sub menu). This is also were the lamp hours will be visible. Also the lamp changer can be initiated if it is unclear which lamp is on. - Improved White Balance: Fast and precise auto-white-tracking Manual White Balance: It is possible to choose manual white balance on the OSD under color settings. It shows R Gain, B Gain and One-Push-WB. When the One-Push-WB was successfully executed all values will be automatically adapted and saved (even through a power off/on cycle). - Improved auto-gain settings - Improved auto-height-adjustment - Improved one-push-auto-focus - Added new RS232 Codes for change lamp and custom serial mode (see serial protocol on WolfVision homepage) - Added new USB commandos for remote control V1.22d: - Internal update only V1.22c: - Internal Update: ImageMirror had a wrong value V1.22a: - Improved help texts - Added new feature: AMX device discovery over RS232 - Fixed bug: Imageturn picture appears correctly in Show All. - Fixed bug: Wrong focus position when preset is recalled. V1.21a: - Added new feature: Mirror vertically and horizontally. Setting is done in the OSD Extra Menue and remains even at power off. - Significantly improved "Auto Height Adjustment" function. The automatism works faster and much more reliable. Attention: There might be a few units, which still don't work properly with this Firmware. Please contact your WolfVision support center. - Fixed bug: Wrong behaviour of Presets, when Power On Preset is set to "off". V1.20a: - Added new resolutions: VGA/60 (640 x 480, 60Hz, 4:3) Required for HDTV XGA 16:9 (1024 x 768, 60Hz, 16:9) Special 16:9 resolution for older plasma monitor WXGA/60 (1366 x 768, 60Hz, 16:9) Resolution for Widescreen monitor WSXGA/60 (1680 x 1050, 60Hz, 16:10) Resolution for Widescreen monitor 720p/50 (1280 x 720, 50Hz, 16:9) HDTV resolution (progressive scan) 720p/60 (1280 x 720, 60Hz, 16:9) HDTV resolution (progressive scan) 1080p/50 (1920 x 1080, 50Hz, 16:9) HDTV resolution (progressive scan) 1080p/60 (1920 x 1080, 60Hz, 16:9) HDTV resolution (progressive scan) - Fixed bug: Image Turn message not disappear on preview monitor when control via RS232 - Fixed bug: sporadic white balance problems V1.13a: - Added new feature: One-Push-Auto-Focus, started by pressing both focus buttons simultaneuosly - new commands for USB Software - Fixed bug: 3-CCD initialization causes color problems - Fixed bug: Extern In produce error messages when Extern In not connected V1.12p: - Automatic p. correction implemented V1.12i: - Internal updates only! V1.12h: - Fixed bug: new defined CCD temperature constant (sometimes vertical stripes at low temperature) V1.12g: - Internal updates only! V1.12f: - Store Power-On Preset added to Power Settings V1.12e: - Image On/Off implemented, assignable to Preset Settings - Iris Priority implemented - Preview Output useable as preview or regular output. If used as preview you get OSD-messages about the current state of the unit (only on the Preview Output). V1.12d: - Internal updates only! V1.12c: - Internal updates only! V1.12b: - Internal updates only! V1.12a: - Fixed a bug in auto-resolution (sometimes wrong refresh-rates were detected/used) - Improved picture-quality on UXGA-DVI V1.11b: - Fixed bug: Unit switched off after 4.25h of inactivity (introduced by V1.10a) V1.11a: - Added SXGA +/- Resolution (1360 x 1024, 60/75Hz) (JVC-DILA) - p. correction implemented V1.10c: - Fixed bug in EEPROM-erase-function (factory-adjustment-use only) V1.10b: - Improved White Balance - Turn off lightfield improved V1.10a: - Improved timing V1.09l: - Turn off the light when lightfield is outside the unit - Improved auto-height-adjustment, short time V1.09k: - Added Shading - adjust speed settings V1.09j: - Reset all presets: focus not set to factory presets V1.09g: - Improved timing V1.09f: - Ethernet: display the Ethernet settings when DHCP selected - Ethernet Bug: timing problem at high temperature V1.09e: - new accu preformance V1.09d: - Bug: demo-mode problems in ShowAll V1.09a: - RS232: added lamp status to GetStatus reply - Improved auto-height-adjustment - Better mirror positioning V1.01a: - Final Timing ?? V1.00z: - Improved timing - Implemented Auto-resolution - Laser preformace implemented - RS232: added some missing commands - shutter limits, because of laser V1.00x: - Improved light-sync-list V1.00w: (Release Candidate - used for Infocomm) - JPEG in Ethernetpart implemented - Bug: lampchanger messages on OSD although no lamp blown - Implemented automatic height adjustment - Preform One-Push-White-Balance can not be selected V1.00s: - Support lampchanger - Implemented demo modus - Implemented macro - Support MEPS200 - 12V oberservation V1.00q: - Better Power On preformance - Correction of RGB204 detail - Improved Auto-Iris V1.00i: - Memories can be stored with RGB204 - new Ethernet menu V1.00d: - Mirror positioning - Improve RGB204 preformance - support several lenses - support SNT100 - Improved Ethernet, DHCP added Based on V1.00b of FB2-firmware